CN45 Counting Matrix Sensor | Dolphin Device
Counting Matrix Sensor · Model CN45

Reliable counting across a 45 × 45 mm optical window.

CN45 is an industrial through-beam multi-channel optical matrix sensor designed for counting and passage detection of small objects. Eight infrared channels cover the sensing window so parts do not need to cross one exact single-beam point.

8 optical channelsIR 950 nm5 mm minimum objectPNP / NPNNormally open
45 × 45 mmActive sensing area
5 × 5 × 5 mmMinimum detectable object
3 mmMinimum object spacing
10–30 V DCSupply voltage
Dolphin Device CN45 counting matrix sensor
8Independent optical channels across the counting window
1 kHzSpecified switching frequency for rapid optical sampling
30 msSpecified response time
10,000 luxMaximum specified ambient-light immunity

How the CN45 works

CN45 is a through-beam counting matrix sensor designed for small parts moving through a controlled opening. Eight infrared optical channels continuously monitor the 45 × 45 mm active area. When an object passes through the window and interrupts one or more channels, the sensor changes its digital output so the connected PLC, counter or controller can register the event.

Detection principle

The sensor uses 8 optical channels across the opening instead of a single point beam. This means the part does not need to cross one exact position. As long as the object passes through the active sensing area and is large enough to interrupt the optical field, CN45 detects it.

The specified light source is IR at 950 nm, with a 45 × 45 mm active sensing area and a minimum detectable object size of 5 × 5 × 5 mm.

What happens when a part passes?

As the part enters the sensing window, one or more beams are interrupted. The internal electronics validate that interruption and change the normally-open PNP or NPN output. The connected controller then increments a count, checks a batch quantity, confirms product flow or performs another programmed machine action.

The CN45 itself provides the detection signal; the actual accumulated count is normally handled by the PLC, counter or machine controller.

1. Guide the parts through the opening

Mount the CN45 so the complete product stream passes through the 45 × 45 mm active sensing zone. A chute, guide or feeder should keep parts away from the frame edges.

2. Separate individual objects

For one count per object, parts must pass individually. Maintain at least the specified 3 mm minimum spacing. Touching or overlapping objects may look like one continuous blockage.

3. Connect the correct output type

Select the PNP or NPN version that matches the PLC or counter input. The output is normally open and changes state when a valid object passage is detected.

4. Use the controller to count

The PLC, counter or microcontroller should count output transitions. It can then stop the feeder at a target quantity, trigger a gate, confirm a batch or monitor production flow.

5. Keep the sensing window clear

Dust, fixed obstructions or product residue inside the opening can create a constant blocked condition. Keep the optical path clean and mechanically unobstructed.

6. Validate speed and spacing

Check the real production rate against the specified 1 kHz switching frequency and 30 ms response time. Also verify that PLC input filtering does not hide short detection pulses.

Best use case: CN45 works best below a bowl feeder, chute or gravity-fed path where small parts fall individually through the opening. It is especially useful when a normal single-point photoelectric sensor could miss parts because their position varies across the stream.
8Optical channels across the counting area
45 × 45 mmActive sensing area
5 × 5 × 5 mmMinimum detectable object
3 mmMinimum object spacing

Applications

CN45 is most useful where many small discrete parts move through a controlled path and a single point sensor would be easy to miss or difficult to align.

Counting small parts falling through a CN45-style optical matrix sensor
Small-part countingCount individual parts falling from a feeder into a bin, bag or assembly station.
Batch quantity verificationStop a feeder when a programmed number of pieces has passed through the sensing window.
Flow / no-flow monitoringUse repeated detection events to confirm that product is still moving through a process.
Jam detectionA continuously blocked window can be used by the controller as a jam or obstruction condition.
Reject / divert controlCount-based logic can operate gates, diverters or packaging mechanisms downstream.
01

Tablets & capsules

Suitable for counting discrete pharmaceutical-style objects when the machine guides and spaces them correctly.

02

Screws & fasteners

Useful after a bowl feeder or chute for counting nuts, screws, washers and similar hardware.

03

Electronic components

Count connectors, housings or other components that are large enough to meet the minimum object-size specification.

04

Plastic molded parts

Monitor small caps, clips, molded pieces and assembly components exiting a feeder.

05

Seeds & pellets

Applicable to individually separated agricultural, food or polymer pieces where environmental conditions are suitable.

06

Packaging machines

Verify piece counts before sealing packets, pouches, bottles, trays or kits.

07

Feeder monitoring

Confirm that a vibratory bowl, linear feeder or gravity chute is continuing to deliver product.

08

Assembly counting

Count supplied components at a workstation or automated assembly cell to verify process quantity.

09

Machine cycle verification

Use part passage as a process confirmation signal before the next machine operation is allowed.

Technical specifications

The values below are captured from the supplied CN45 technical information.

Optical & performance
ModelCN45
Detection principleThrough-beam multi-channel optical array
Active sensing area45 × 45 mm
Number of optical channels8
Light sourceIR, 950 nm
Minimum detectable object5 × 5 × 5 mm
Minimum object spacing3 mm
Switching frequency1 kHz
Response time30 ms
Ambient-light immunity10,000 lux max.
Status indicationPower and output LEDs
Electrical & mechanical
Supply voltage10–30 V DC
Current consumption30 mA at 24 V
Output typePNP / NPN
Output functionNormally open
Short-circuit protectionProvided
Reverse-polarity protectionProvided
Housing materialSteel / ABS
Nominal housing size85 × 85 mm
Approx. weight120 g

Mechanical dimensions

The detailed drawing gives the exact mechanical envelope and mounting geometry. The active optical area is specified separately as 45 × 45 mm.

CN45 mechanical dimensional drawing
85.13 mmOverall width
84.96 mmOverall height
14.00 mmOverall thickness
46.60 mmPhysical window width shown in drawing
44.74 mmPhysical window height shown in drawing
Ø 4.40 mmMounting-hole diameter

Active area vs. physical opening

The mechanical window dimension and the optical active-area specification are not necessarily identical. For application design, use 45 × 45 mm as the specified active sensing area and use the drawing dimensions for mechanical fit.

Installation and application guidance

Good mechanical presentation of the parts is as important as the sensor itself. These points are the main things to check during machine integration.

Keep the stream inside the window

Guide parts so they pass through the active region rather than clipping the outer frame or mounting hardware.

Maintain object separation

Keep at least 3 mm spacing when individual counting is required. Mechanical singulation is recommended.

Respect minimum object size

Use objects at or above the 5 × 5 × 5 mm specification. Validate unusual shapes or orientations in the actual machine.

Choose PNP or NPN correctly

Match the CN45 output type to the PLC, counter or controller input architecture used by the machine.

Keep the window clean

Dust, product residue or fixed obstructions inside the optical path can appear as a constant blockage.

Validate real production speed

Check actual part velocity, spacing and PLC input filtering against the specified 1 kHz switching frequency and 30 ms response time.

Application note: CN45 is an industrial object-counting and passage-detection sensor. It should not be treated as a personnel-safety device unless the exact product has the required safety certification for that use.

Frequently asked questions

Why use eight optical channels?

Multiple channels cover more of the opening than a single point beam. This makes the sensor better suited to falling parts that may not follow one perfectly fixed path.

Does CN45 itself display the count?

The CN45 provides the detection output. A PLC, counter or other controller normally accumulates the output events and displays or acts on the final count.

Can two parts be counted if they touch?

If two objects enter together or remain optically connected, they can look like one blockage. For accurate piece counting, separate the parts mechanically.

Does object color matter?

Because CN45 uses a through-beam principle, detection is based primarily on interruption of the light path instead of light reflected from the target surface.

Dolphin Device · CN45 Counting Matrix Sensor

Industrial small-part counting, flow detection and batch-verification sensor.

Quick Navigation