SENSING POSSIBILITIES. ENGINEERING CONFIDENCE.Technical assistance
Through-beam

M18 Through Beam Sensor TX RX type NPN NO Sn: 5 Metre

Separate transmitter and receiver units detect objects interrupting the beam.

5 m
Sensing range
NPN / NO
Output
Cable
Connection
M18
Housing
10-35 VDC
Supply
NON flush
Mounting
PRODUCT SPECIFICATIONS

Technical data

M18 Through Beam Sensor TX RX type NPN NO Sn: 5 Metre Catalog reference
Technical specifications for M18 Through Beam Sensor TX RX type NPN NO Sn: 5 Metre
Sensing01
TechnologyThrough-beam
ManufacturerDolphin
Housing / formM18
Sensing range5 m
Electrical02
Operating voltage10-35 VDC
Output circuitNPN
Switching functionNO
Maximum load current300mA
Mechanical03
ConnectionCable
Wire count3
Wiring notesCatalogue audit 25 October 2026: 3 conductors recorded from explicit, consistent product notation (Output: NPN NO 3 wire). Source-based catalogue value; wiring diagram and terminal assignment still require verification.
Cable length3 m EACH TX AND RX
MountingNON flush
Housing materialMetallic Nickel plated
Dimensions / length65 mm
Dimensional reference04
Body diameter18 mm
Housing length (excluding tip)65 mm
Data source & verification

Based on Dolphin’s supplied product information. Confirm the exact orderable configuration with the team.

DOCUMENTATION

Downloads

Manufacturer documentation is not attached. Request the exact wiring and dimensional reference before installation.

Is this the right sensor for your application?

Start with your target and installation to compare suitable configurations.

Use the sensor finder